Print |  Close this window

XMD Differential Process pressure transmitter

Minimum pressure range
75 mbar
Maximum pressure range
20 bar
Maximum Line Pressure
130 Bar
Reference
Differential only
Output
4-20mA/2-wire, HART Communication optional.
Supply Voltage
12 - 30V dc
Accuracy
turn-down ≤ 5:1: ≤ ± 0.1 % FSO turn-down > 5:1: ≤ ± [0.1 + 0.015 x turn-down] % FSO with turn-down = nominal pressure range / adjusted range
Process Connection
Internal thread 1/4 - 18 NPT
Electrical Connection
Internal Terminal Clamps
IP Rating
IP67
Diaphragm Material
Stainless steel 1.4435 (316 L) , optional: Hastelloy® C-276 (2.4819)
Process Connection Material
Stainless steel 1.4401 (316)
Display type
LC display, visible range 32.5 x 22.5 mm; 5-digit 7-segment main display, digit height 8 mm, range of indication ±9999; 8-digit 14-segment additional display, digit height 5 mm; 52-segment bargraph; accuracy 0.1% ± 1 digit
Temperature Range
-40 to +125°C
Optional Extra's
ATEX Ex ia, Ex D Versions, HART Communication, Integrated display, prepared for chemical seals, linear or square root extraction
Approvals
ATEX Approval Ex ia & Ex d
Product Downloads

The differential pressure transmitter XMD has been especially designed for the process industry and can be used for level measurement of closed, pressurized tanks, pump or filter control-ling, etc.

Another attribute is the possibility to switch the output signal from linear to square root extraction by what the flow rate of the medium can be issued.

Print |  Close this window